Structural Steel Detailing Study – Mixed-Use Condo Project, USA
Facade Detailing Case Study – Commercial Office Tower Project, USA
2 AND U is a meticulously designed office tower located at Second and University, combining modern aesthetics with functional space.
Advenser’s involvement in this project focused on the creation of precise shop drawings using AutoCAD. The profile system for the building’s façade included ultra-thermal curtainwall and storefront systems, as well as doors, ensuring high-performance and energy efficiency.
The project presented several complexities due to the intricate and specific design, including sloped and interconnected curtainwalls. The custom details required to achieve the precise angles and slopes posed unique challenges. Advenser worked closely with the design team to ensure these details were accurately represented in the shop drawings, facilitating seamless construction and compliance with design intent.
Rebar Detailing Case Study – Museum of The Future Project, UAE
Museum of The The Museum of the Future is a truly unique project. Advenser was tasked with detailing rebar elements using Tekla Structures and extracting the required deliverables, including drawings, Bar Bending Schedules (BBS), IFC files, and Tekla BIM site models. These were essential to facilitate the construction of the ring beam and internal beams. The “ovoid” shape of the ring beam posed significant challenges for rebar detailing using traditional 2D software. Consequently, the client opted for 3D modeling, which also helped detect clashes prior to installation. The project involved the highly complex task of modeling a large number of curved rebars, made even more demanding by tight schedules.In total, 861 tons of rebar were detailed for the project.Project
Structural Steel Detailing Case Study – Commercial Sales & Service Infrastructure Project, USA
The South Jersey Yacht Sales project involved detailing of steel structures, including steel framing for the foundation, mezzanine floor, roof, and various miscellaneous elements such as stairs and railings, exterior ramp and stair railings.
MEP BIM Case Study – Muilt-Storey Mixed-use Building Project, Cayman Islands
Advenser provided Mechanical, Electrical & Plumbing modelling, coordination, and shop drawing services for 90 Nexus, a 10-floor mixed-use building with a roof, developed by Dart in the Cayman Islands.
MEP BIM Case Study – Mixed-Use Tower Project, USA
The scope involved utilizing AutoCAD MEP to create precise electrical designs for prefabrication. This included calculating accurate wire cut lengths to reduce waste and ensure proper installation. Detailed drawings were developed to represent all components accurately, ensuring efficient assembly during the prefabrication process.
Structural Detailing Case Study – Mixed-use Building, USA
Steel team was assigned with both main steel and miscellaneous steel detailing for the project, which involved a complex and heavy structure. The design featured massive beams of varying profiles, each connecting to a central column in four directions with moment connections. This posed a significant challenge, as the bolted connections often led to bolt clashes due to the varying beam depths. Our team worked diligently to resolve these clashes, ensuring erection feasibility on-site. Additionally, we collaborated closely with structural engineers and Architect and the EOR to convey the challenges and secure their understanding and approval to proceed effectively.Advenser also provided design calculations, with the design team delivering excellent results in this regard. Our scope of work included developing a detailed 3D structural steel model using Tekla Structures, incorporating all primary and miscellaneous steel elements. Comprehensive drawings and reports were generated to support the construction of the steel structure, adhering to AISC, AWS, and OSHA standards. Deliverables encompassed erection drawings, fabrication drawings, and single-part drawings, along with Tekla-generated reports such as ABM, BOM, NC files, KISS files, bolt lists, stud lists, and DXF files to facilitate seamless construction workflows.
Miscellaneous Steel Detailing Study – Mixed-Use Condo Project, USA
The project encompassed a comprehensive scope of work, including the detailing of stairs, railings, mezzanine framing, storefront structures, canopies, feature columns, elevator details, coffee shop elements, roof framing for Building B, BBQ canopies, privacy and parking screens, gates, fences, mechanical screens, HVAC supports, and more. The development spanned Buildings A, B, and C, each comprising 44 floors, with Building A featuring a dedicated commercial area. Our primary responsibility involved the intricate detailing of the stair structures and railings, a complex task given the continuous elevation from two lower levels to the 42nd floor. Additionally, the skewed roof structure of Building B presented unique challenges, requiring precise connections aligned with client specifications. Frequent design changes during the submission process and tight deadlines further added to the complexity of the project. A critical aspect of the deliverables was producing drawings with dimensions in both metric (mm) and imperial (feet and inches) units to accommodate fabrication in China and subsequent shipping to Hawaii.
Advenser’s role included developing a detailed 3D structural steel model using Tekla Structures, incorporating both primary and miscellaneous steel components. From this model, the team generated comprehensive erection, fabrication, and single-part drawings, along with Tekla-generated reports such as ABM, BOM, NC files, KISS files, bolt lists, stud lists, and DXF files. These deliverables were designed to streamline the construction process and adhered to AISC, AWS, and OSHA standards, ensuring precision and compliance.
Facade Detailing Case Study – Commercial Infrastructure – Office Facility, USA
Ferguson Enterprises Headquarters is the corporate hub for the largest U.S. supplier of plumbing, heating, air conditioning, and other appliances.Advenser’s involvement in this project centered on the development of detailed shop drawings using AutoCAD. The façade system utilized captured and structural glazed curtainwall and storefront systems, along with doors, designed to meet both aesthetic and functional requirements.The project presented coordination challenges due to the number of interconnected and angled frames. Additionally, provisions for sunshade installations were included, requiring careful detailing for future integration by others. Custom anchors were also required to ensure stability and alignment with the building’s unique design. Advenser worked meticulously to address these challenges, delivering precise drawings that met the project’s complex specifications
Structural Detailing Case Study – Commercial Public Mall, UAE
The project involves the new construction of a commercial public mall at NAS Al SHEBA, Dubai. Our work is centered around developing the LOD 300 model, along with LOD 400 sheets. Specifically, we are focusing on the substructure of the building, which includes the general arrangement drawings, excavation plans, and DEWA trench drawings.
MEP BIM Case Study – Municipal Complex Project, USA
Mckinney Municipal Complex is a government building project which involved in modeling and coordination of mechanical and plumbing systems for a new facility located in Mckinney, Texas.
Architectural BIM Case Study – Residential Condominium Tower Project, USA
The project is modelling the architecture & structure part of the building in Hawaii. Situated in the Keeaumoku street, Honolulu Hawaii.
Steel Detailing Case Study – Fitness Centre, USA
LAF Pompano is a fitness club with 2 stories covering an area of 57000 sq.ft. The requirement was to model steel elements and Advenser created models and drawings as per AISC, AWS & OSHA requirements.
Facade Detailing Case Study – Commercial Building, Saudi Arabia
Advenser’s scope of services in the project consisted of remarks modification of previous drawings, preparation of new drawings, fabrication drawings, material calculations, curtain wall structural calculations and necessary 3D models as per the Architectural and building structural drawing.
Facade Detailing Case Study – Commercial & Residential Complex, Netherlands
Bestuurskantoor Aruba is an elliptical shaped Residential cum commercial complex located in Aruba, Netherlands comprising of External & Internal curtain walls, ACP cladding, Balustrades, Canopies, Doors & windows and External Awnings.
Precast Detailing Case Study – Commercial Building, Australia
We created a sample for a particular level and had shown client for general comments. After getting the feedback we started creating other sheets. We used color in the drawings for identifying elements, elevations and footings in our output, which helped client in quick segregation.
Steel Detailing Case Study – Event Space and Private Car House, USA
Shore car club is a 40,000 square foot members club, event space and private car house for collectors and enthusiasts. We supported the structural steel detailing of different structures of the building, such as the foundation, the second floor level, the roof, and various interior components.
Architectural BIM Case study – BIM Content Creation
The project involves the creation of parametric families with different types of partition families. Inputs from the client included detailed specification set in CAD and pdf formats and also iges files for modeling the irregular shapes. Advenser delivered Revit model for commercial purpose.
Architectural BIM Case study – Hotel & Apartments, UAE
Montrose-1 & 2 was a residential and hotel apartment development by Deyaar PJSC. The project consists of three 20 story towers.
Architectural BIM Case Study – BIM Content Creation
Inputs from the client included detailed specification sets in CAD and pdf formats and also iges files for modeling the irregular shapes. Simple Spec doors consist of five unique doors with sliding and pivot operations, with each door differing by the guide through which it slides.
MEP BIM Case Study – Research Center USA
MEP BIM Case Study of an office building – Modeling of plumbing and electrical conduits from point cloud data.
MEP BIM Case Study – Office Building, USA
In Google Kirkland campus, located in Washington, a new 2 story office building was proposed to suit existing office building over one level of structured parking.
MEP BIM Case Study – Commercial Building, USA
The Honda-Toyota facility project in Seattle covering an area of 480,000 sq. feet required Advenser to model, coordinate and use this model for all other future showrooms.
MEP BIM Case Study – BIM Content Creation, USA
We had to deliver Revit families of hanger components and seismic hangers as per the catalogue information and equipment list provided in excel format.
MEP BIM Case Study – Residential & Commercial Building, USA
This construction project involved a 150,000 sq. ft. residential and commercial building including 140 multi-family dwelling units with 15% MPDUs as well as 7,000 square feet of retail space along the Arlington Road property frontage.
Integrated BIM Case Study – Residential & Commercial Tower, UAE
The Proposed Residential Development is comprised of the 40-story tower, which sits tall over a distinct 5-story podium base (G+M+4 Podiums) which acts as the base for the tower.
BIM Services
Architectural
Structural
MEP
Facade